Diagnostics & Testing

ELC‑ID

Know what the refrigerant is before you charge.

The ELC‑ID identifies R134a and R1234yf refrigerants in a vehicle or cylinder as a percentage, using an NDIR sensor. Contaminated or mixed refrigerant is caught before it can damage your service unit or the vehicle's compressor.

R134a / R1234yf

Made in Türkiye
2-year warrantyDirect from the manufacturer
Technical support
User trainingInstallation and training included
  • %purity result, as a percentage
  • 2 min 20 stest time
  • <5 gsample per test
  • 4,3"colour touchscreen
  • 12–24 Vpowered from the vehicle battery
  • 3 kgmetal housing with hook

Who it's for

Know what the refrigerant is before you charge

Mixed or contaminated refrigerant is one of the most common causes of damage to the recovery unit's filter and the vehicle's compressor. A two-minute analysis prevents an expensive repair.

  • Service station owners

    Analyse every vehicle before recovery, so the unit's tank and drier filter are protected from contaminated refrigerant.

  • Authorised service centres

    Document refrigerant quality for the customer and the brand; the result is reported by e‑mail.

  • Refrigerant traders and wholesalers

    Verify the purity of the refrigerant in a cylinder before buying or selling.

Key features

Precise identification every time

% purity with an NDIR sensor

The non-dispersive infrared sensor identifies R134a or R1234yf as a percentage, so you make the service decision quickly and with confidence.

4.3" colour touchscreen

User-friendly interface; results are clearly shown on screen.

Wi‑Fi updates and e‑mail reports

Software updates arrive over Wi‑Fi; analysis results are sent directly by e‑mail, with no paper waste.

12–24 V from the vehicle battery

No external power supply needed; works with 12 V and 24 V systems.

Reverse-connection protection

Reverse-polarity protection for the positive and negative terminals.

Rugged metal housing and hook

A housing that withstands knocks and drops; hangs under the bonnet from its integrated hook.

Optional thermal printer

A printer version for those who want a printed result.

Result memory

The results of the last 5 tests are stored on the unit; USB 3.0 and RS232 connections.

How to use

Connect, start,
result in 2 minutes 20 seconds

The unit is powered from the vehicle battery, connects to the service port or cylinder with an adapter, and completes the analysis with less than 5 grams of sample.

  1. 01Battery connection (12–24 V)
  2. 02Vehicle / cylinder connection with adapter
  3. 03Sampling (<5 g)
  4. 04Analysis
  5. 05Result: % and e‑mail
  • 2 min 20 stest time
  • <5 gsample; almost no refrigerant is taken from the vehicle
  • 5 testsresults stored in the unit's memory

Specifications

ELC‑ID in numbers

Refrigerant typeR1234yf ve R134a
Result unit% (percentage)
Sensor typeNDIR (non-dispersive infrared)
Operating pressure1.5–12 bar (22–174 psi)
Sample quantity< 5 g / test
Test period2 minutes 20 seconds
Operating temperature+10 … +49 °C
Power12–24 V DC (vehicle battery)
PortUSB 3.0, RS232
PrinterThermal (optional)
Result storage5 tests
Dimensions (W × D × H)9,5 × 21,5 × 27,5 cm
Weight3 kg (kit with case 5.2 kg; case 37 × 14 × 44 cm)
ApprovalsCE

Frequently Asked Questions

What people ask before buying

Why is refrigerant analysis necessary?

Refrigerant that is mixed (R134a + R1234yf) or contains air or foreign gases gets into your service unit's tank and filter and damages the vehicle's compressor and cooling performance. Analysis takes two minutes; a repair takes days and costs thousands. For details, see the blog article "Why refrigerant analysis matters".

Does the ELC‑ID measure R744 (CO₂)?

No. The ELC‑ID is designed for R134a and R1234yf refrigerants.

Can I give the result to my customer?

Yes. The result is sent by e‑mail over Wi‑Fi; an optional thermal printer can be added for a printed copy.

How is the software updated?

The unit connects to the internet via Wi‑Fi and downloads updates itself; you always stay on the latest version.

How do warranty and service work?

Recharging units carry a 2-year manufacturer's warranty. On-site service is provided across Türkiye within 24–48 hours; labour after a repair is covered by an additional 6-month warranty. Service is provided by the team that designed and built the unit. For a fault under warranty the process has four steps: notification and registration, assessment, repair, testing and delivery; details are on the technical service page. on the technical service page.

Yes. The unit is installed on site, the scales and vacuum are calibrated, and your technicians receive user training. The user manual and training videos are also available on our YouTube channel.

Quote

Get a price and lead time for the ELC‑ID

Tell us briefly what you need; we will send the right configuration, lead time and any current offers within the same business day.

Get a Quote

ELC‑ID · reply within the same business day

* Fields marked * are required.